Search results for " Subtraction"
showing 10 items of 68 documents
On the importance of background subtraction in the analysis of coronal loops observed with TRACE
2010
In the framework of TRACE coronal observations, we compare the analysis and diagnostics of a loop after subtracting the background with two different and independent methods. The dataset includes sequences of images in the 171 A, 195 A filter bands of TRACE. One background subtraction method consists in taking as background values those obtained from interpolation between concentric strips around the analyzed loop. The other method is a pixel-to-pixel subtraction of the final image when the loop had completely faded out, already used by Reale & Ciaravella 2006. We compare the emission distributions along the loop obtained with the two methods and find that they are considerably differen…
12C(p,p′) scattering measurement at forward angles
2006
Experimental method of measuring inelastic proton scattering with high-resolution at forward angles including zero degrees has been developed. An energy resolution of 20 keV and a scattering angle resolution of 0.5 degrees have been achieved as well as low background condition and a reliable background subtraction method. The experimental technique was applied to the 12 C (p,p′) reaction for studying the property of the second 0+ state at 7.7 MeV and a broad bump around Ex~10 MeV , where the presence of a 2+ state was reported from the 12 C (α,α′) measurement. Preliminary spectra and angular distributions are shown.
Vertical ground reaction force measurements and video measurements provide comparable estimates of distance moved by mice during artificial light and…
2011
Video-based measures of spontaneous activity of rodents are of interest in studying, e.g. physiology. However, video-based tracking methods typically require light. The purpose of the present study was to develop a video based method for tracking movements of mice during a dark period. The method was applied in comparing the dark and light period activities of mice. Ten male mice were used in the present study. The activity of the animals was monitored simultaneously with video and ground reaction force (GRF) recordings during consecutive 12h periods of artificial light and dark. Texture based background subtraction method was used to track the mouse from the video recording, while the weig…
Multispectral images-based background subtraction using Codebook and deep learning approaches
2020
This dissertation aims to investigate the multispectral images in moving objects detection via background subtraction, both with classical and deep learning-based methods. As an efficient and representative classical algorithm for background subtraction, the traditional Codebook has first been extended to multispectral case. In order to make the algorithm reliable and robust, a self-adaptive mechanism to select optimal parameters has then been proposed. In this frame, new criteria in the matching process are employed and new techniques to build the background model are designed, including box-based Codebook, dynamic Codebook and fusion strategy. The last attempt is to investigate the potent…
Radiation exposure in vascular angiographic procedures.
2012
Abstract Purpose To evaluate dose reduction in vascular angiographic procedures by using fluoroscopy capture instead of digital subtraction angiography frames for documentation. Materials and Methods A total of 764 consecutive vascular interventional procedures performed over a period of 1 year were retrospectively analyzed with respect to the fluoroscopy time and the resulting dose–area product (DAP), the DAP of the radiographic frames, and the overall DAP. Results A total of 70% of the total DAP was a result of the acquisition of radiographic frames, leaving only 30% being applied by fluoroscopy. Conclusions Fluoroscopy capture should be used for documentation whenever possible. A registr…
A multicenter 12-month experience with a new iliac side-branched device for revascularization of hypogastric arteries.
2016
Abstract Objective The aim of this study was to investigate the 1-year safety and efficacy of a new iliac side-branched device (IBD) for revascularization of the hypogastric arteries. Methods Patients receiving the E-liac (Jotec GmbH, Hechingen, Germany) side-branched device at six German vascular centers either as a stand-alone procedure or in combination with abdominal aortic aneurysm exclusion were included in a prospectively created data bank. Collected data were analyzed for baseline characteristics, procedural events, and clinical follow-up; variables included endoleaks, reinterventions, and internal iliac artery (IIA) patency. Results Between January 2012 and January 2015, a total of…
A new concept to treat lumbar spine stenosis in a mini invasive way
2017
Immunity and other defenses in pea aphids, Acyrthosiphon pisum
2010
Background Recent genomic analyses of arthropod defense mechanisms suggest conservation of key elements underlying responses to pathogens, parasites and stresses. At the center of pathogen-induced immune responses are signaling pathways triggered by the recognition of fungal, bacterial and viral signatures. These pathways result in the production of response molecules, such as antimicrobial peptides and lysozymes, which degrade or destroy invaders. Using the recently sequenced genome of the pea aphid (Acyrthosiphon pisum), we conducted the first extensive annotation of the immune and stress gene repertoire of a hemipterous insect, which is phylogenetically distantly related to previously ch…
Analysis of a multi-wavelength time-resolved observation of a coronal loop
2005
Several items on the diagnostics and interpretation of coronal loop observations are under debate. In this work, we analyze a well-defined loop system detected in a time-resolved observation in several spectral bands. The dataset includes simultaneous images in the TRACE 171 A, 195 A and 284 A bands, and Yohkoh/SXT, and two rasters taken with SoHO/CDS in twelve relevant lines. The loop is initially best visible in the TRACE 195 A filter band, and later in the 171 A filter band, with correspondence with the CDS raster images at log T \~ 6.0-6.1. We have taken as pixel-by-pixel background the latest TRACE, Yohkoh and CDS images where the loop has faded out. We examine the loop morphology evol…
Basics of Image Interpretation in Interventional Neuroradiology
2011
The majority of patients with cerebral vascular diseases, demanding neuroradiological interventions are those, who present with potential life-threatening spontaneous intracranial/intracerebral haemorrhages due to cerebral aneurysms or/and arteriovenous malformations (AVMs) or with cerebral infarction due to intra-arterial thrombi in cerebral arteries. Neuroradiological procedures (interventional neuroradiology) (IN), always, performed in general anaesthesia can be divided into occluding and opening interventions.